Review





Similar Products

99
Thermo Fisher bca protein assay kit thermo fisher scientific 23225 cell titer glo luminescent cell viability assay promega g7573 mycoplasma detection kit pcr
Bca Protein Assay Kit Thermo Fisher Scientific 23225 Cell Titer Glo Luminescent Cell Viability Assay Promega G7573 Mycoplasma Detection Kit Pcr, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pm42156502-223-117-121?v=Thermo+Fisher
Average 99 stars, based on 1 article reviews
bca protein assay kit thermo fisher scientific 23225 cell titer glo luminescent cell viability assay promega g7573 mycoplasma detection kit pcr - by Bioz Stars, 2026-07
99/100 stars
  Buy from Supplier

98
Cytiva Europe protein antibody complexes
Protein Antibody Complexes, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pmc12981022-108-1-11?v=Cytiva+Europe
Average 98 stars, based on 1 article reviews
protein antibody complexes - by Bioz Stars, 2026-07
98/100 stars
  Buy from Supplier

86
Cowin Biosciences bca protein detection kit
Bca Protein Detection Kit, supplied by Cowin Biosciences, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pmc13266507-130-6-13?v=Cowin+Biosciences
Average 86 stars, based on 1 article reviews
bca protein detection kit - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Nature Biotechnology single molecule nzyme linked immunosorbent assay detects serum proteins
Single Molecule Nzyme Linked Immunosorbent Assay Detects Serum Proteins, supplied by Nature Biotechnology, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pm42261770-286-11-21?v=Nature+Biotechnology
Average 86 stars, based on 1 article reviews
single molecule nzyme linked immunosorbent assay detects serum proteins - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Epizyme Inc bca protein detection kit
Bca Protein Detection Kit, supplied by Epizyme Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pm42240802-85-1-6?v=Epizyme+Inc
Average 86 stars, based on 1 article reviews
bca protein detection kit - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Nanjing Jiancheng Bioengineering Research Institute Co Ltd bicinchoninic acid bca protein detection kit
Bicinchoninic Acid Bca Protein Detection Kit, supplied by Nanjing Jiancheng Bioengineering Research Institute Co Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pmc13271076-131-13-19?v=Nanjing+Jiancheng+Bioengineering+Research+Institute+Co+Ltd
Average 86 stars, based on 1 article reviews
bicinchoninic acid bca protein detection kit - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Nacalai protein detection
Protein Detection, supplied by Nacalai, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/bio_rxiv__64898__2026__05__12__724547-251-37-46?v=Nacalai
Average 86 stars, based on 1 article reviews
protein detection - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

99
Thermo Fisher bca protein detection kit
Bca Protein Detection Kit, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pmc13007278-52-27-31?v=Thermo+Fisher
Average 99 stars, based on 1 article reviews
bca protein detection kit - by Bioz Stars, 2026-07
99/100 stars
  Buy from Supplier

94
Sino Biological biotinylated recombinant human nephrin detection protein
Assay to detect <t>nephrin</t> autoantibodies.
Biotinylated Recombinant Human Nephrin Detection Protein, supplied by Sino Biological, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/protein+detection/pmc13103983-60-0-7?v=Sino+Biological
Average 94 stars, based on 1 article reviews
biotinylated recombinant human nephrin detection protein - by Bioz Stars, 2026-07
94/100 stars
  Buy from Supplier

Image Search Results


Assay to detect nephrin autoantibodies.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Assay to detect nephrin autoantibodies.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques:

Detection of serum anti-nephrin autoantibodies by ELISA. (a) Serum levels of anti-nephrin autoantibodies in patients with minimal change disease (MCD), primary focal segmental glomerulosclerosis (pFSGS), membranous nephropathy (MN), lupus nephritis (LN), diabetic nephropathy (DN), IgA nephropathy (IgAN), and healthy controls. (b) Positive rates of anti-nephrin autoantibodies in the same cohorts.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Detection of serum anti-nephrin autoantibodies by ELISA. (a) Serum levels of anti-nephrin autoantibodies in patients with minimal change disease (MCD), primary focal segmental glomerulosclerosis (pFSGS), membranous nephropathy (MN), lupus nephritis (LN), diabetic nephropathy (DN), IgA nephropathy (IgAN), and healthy controls. (b) Positive rates of anti-nephrin autoantibodies in the same cohorts.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques: Enzyme-linked Immunosorbent Assay

Serum anti-nephrin autoantibody profiles across disease activity states in patients with MCD. (a) Serum levels of anti-nephrin autoantibodies in patients during active phase, partial remission (PR), and complete remission (CR). (b) Positivity rates of anti-nephrin autoantibodies across disease activity states. * p < 0.05, ** p < 0.01, *** p < 0.001.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Serum anti-nephrin autoantibody profiles across disease activity states in patients with MCD. (a) Serum levels of anti-nephrin autoantibodies in patients during active phase, partial remission (PR), and complete remission (CR). (b) Positivity rates of anti-nephrin autoantibodies across disease activity states. * p < 0.05, ** p < 0.01, *** p < 0.001.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques: Activity Assay

Correlations between serum anti-nephrin autoantibody levels and key clinical parameters.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Correlations between serum anti-nephrin autoantibody levels and key clinical parameters.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques:

Comparison of clinical characteristics between patients positive and negative for anti-nephrin autoantibodies. * p < 0.05, ** p < 0.01, *** p < 0.001.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Comparison of clinical characteristics between patients positive and negative for anti-nephrin autoantibodies. * p < 0.05, ** p < 0.01, *** p < 0.001.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques: Comparison

Anti-nephrin autoantibody IgG subclasses in patients with MCD. (a) Proportion (%) of IgG subclasses among anti-nephrin autoantibodies. (b) Correlation of anti‑nephrin-IgG4 with total anti‑nephrin-IgG. (c) Ratios of anti-nephrin-IgG subclasses indicative of Th1/Th2 skewing: IgG1/IgG4 and IgG3/IgG4.

Journal: Annals of Medicine

Article Title: Association between anti-nephrin autoantibodies and disease activity in minimal change disease

doi: 10.1080/07853890.2026.2661115

Figure Lengend Snippet: Anti-nephrin autoantibody IgG subclasses in patients with MCD. (a) Proportion (%) of IgG subclasses among anti-nephrin autoantibodies. (b) Correlation of anti‑nephrin-IgG4 with total anti‑nephrin-IgG. (c) Ratios of anti-nephrin-IgG subclasses indicative of Th1/Th2 skewing: IgG1/IgG4 and IgG3/IgG4.

Article Snippet: Biotinylated recombinant human nephrin detection protein (17757-H08H, Sino Biological), diluted 1:20,000, was added to the Protein G plates (100 μL/well) and incubated at 37 °C with shaking at 700 rpm for 60 ± 5 min, followed by washing three times with PBST.

Techniques: